1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CABLE
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CABLE
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CABLE
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CABLE
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CABLE
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CABLE
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CABLE
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CABLE
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CABLE
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CABLE
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CABLE
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CABLE

1 / 5

1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CABLE

Obtenir le dernier prix
envoyer une demande
Model No. : YJY62
Brand Name : HUAYUAN YONGTONG
Type : Insulated
Conductor Type : Stranded
Application : Underground
Conductor Material : Copper
Sheath Material : Crosslinking
Insulation Material : XLPE
Material Shape : Round Wire
Certification : ISO9001
Brand : HUAYUAN YONGTONG
plus
8yrs

Beijing, Beijing, China

Visiter le magasin
  • Certification de plate-forme
  • Vidéo

Description du produit

1. NORMES APPLICALBE

Le câble offert par Beijing Huayuan doit être conçu, fabriqué et testé conformément aux normes internationales suivantes:

Quality Control Standard

ISO 9001

Quality Management Systems

ISO 14001

Environmental Management Systems

Component Material Standard

IEC 60228

Conductors of insulated cables

Cable Standard

IEC 60502-2

Power cables with extruded insulation and their  accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) –

Part 2:Cables for rated voltages from 6 kV (Um = 7,2 kV)

up to 30 kV (Um = 36 kV)


2.CABLES STRUCTURE pour 1C * 400mm2 Câble

cable1



CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV 1 × 400/35 mm2

Construction

Nominal Thickness(mm)

Nominal Diameter(mm)

1- Stranded compacted circular copper conductor

/

23.2

2- Conductor screen

0.8

24.8

3- XLPE insulation

8.0

40.8

4- Insulation screen

0.6

42.0

5- Semi-conductive water-blocking tape

0.3

42.3

6- Copper wire with copper tape screen

Nominal cross section 35mm2

44.6

7- Wrapping tape

0.2

45.2

8- PVC inner sheath

1.5

48.2

9- Aluminum wire armour

2.5

53.2

10-Wrapping tape

0.25

54.7

11-PVC Outer sheath

2.8

60.3


3.Caractéristiques techniques garanties

N2XSYRY

18/30 KV Power Cable- CU/XLPE/SCRlBDlAWAlPVC

Size 1x400 Sqmm

Size 1x400 Sqmm





Item

Description

Specification

offer

1

No. ofCores

1

1

2

Conductor Material

Cu

Cu

3

Conductor size

400 mm²

400 mm²(nominal)

4

No. And diameter of wires (No/mm)

61x2.85

60x2.97(nominal)

5

Conductor Diameter

~22.5 mm

23.2mm(nominal)

6

Thickness of inner semi-conductor layer

~ 0.8 mm

0.8mm(nominal)

7

Diameter over inner semi-conductor layer

~22 mm

24.8mm(nominal)

8

Insulation material

XLPE

XLPE

9

THickness of insulation, nominal

~6 mm

8.0mm(nominal)

10

Diameter over insulation,nominal

~33 mm

40.8mm(nominal)

11

Thickness of outer semi-conductor layer

~0.5 mm

0.6mm(nominal)

12

Diameter  of outer semi-conductor layer

35 mm

42.0mm(nominal)

13

Semi-conductor & water blocking tape thickness

0.3 mm

0.3mm(nominal)

14

Nominal crosssection of screen

35 mm²

35 mm²

15

Screen specification

Copper wire &copper tape applied helically

Copper wire &copper tape applied helically

16

Specification sheath material

PVC (ST2)

PVC (ST2)

17

Thickness of separation sheet

~ 40 mm

1.5mm(nominal)

18

Diameter of armour wires

Alumininum & 2.5 mm

2.5(nominal,AL wire)

19

Diameter of over amouring

 ~ 44 mm

53.2(nominal)

20

Outer sheet material

PVC (ST2)

PVC (ST2)

21

Thickness of outer sheath, nominal

2.5 mm

2.8 mm(nominal)

22

Overal diameter

~50 mm

60.3(nominal)

23

AC test voltage for 5 min (For fisrt time)

70 KV

70 kV

24

Cable color

Red

red


4. EXIGENCES DE TEST POUR les câbles d'alimentation MT

L'essai de câble doit être effectué conformément à la norme applicable des câbles d'alimentation de 18 / 30kV. Les éléments d'essai suivants doivent être réalisés conformément aux normes CEI pertinentes.

No.

Test item

Routine tests

1

measurement of the electrical resistance of conductors

2

Partial discharge test

3

Voltage test

Sample tests

1

conductor examination

2

check of dimensions

3

Voltage test for 4 h

4

Hot set test for XLPE insulation



Notre compagnie

Factory-1


Atelier


undefined

Paquet

undefinedundefined

Livraison et paiement

undefined

undefined


Honneur

undefined

Client d'heure

undefined


1.Trois conducteur en cuivre de noyau conducteur en cuivre de noyau de 2.Five câble d'alimentation de 3.High tension 4. câble de 33kv câble 5.Construction fil métallique armé de 6.Steel câble 7.Steel eArmoured

envoyer une demande

Alerte du produit

Abonnez-vous à vos mots clés intéressés. Nous enverrons librement les produits les plus récents et les plus chauds de votre boîte de réception. Ne manquez aucune information commerciale.