1 / 5
Model No. : | YJV |
---|---|
Brand Name : | HUAYUAN YONGTONG |
Type : | Insulated |
Beijing, Beijing, China
Description du produit
1. NORMES APPLICALBE
Le câble qui Beijing Huayuan Gaoke Cable Co., Ltd. offerts doivent être conçus, fabriqués et testés conformément aux normes internationales suivantes:
Quality Control Standard |
|
ISO 9001 |
Quality Management Systems |
ISO 14001 |
Environmental Management Systems |
Component Material Standard |
|
IEC 60228 |
Conductors of insulated cables |
Cable Standard |
|
IEC 60502-1 |
Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) – Part 1:Cables for rated voltages of 1kV(Um=1.2kV) and 3kV(Um=3.6kV) Fire retardant according to IEC/EN 60332-3-24 |
2.
CABLES STRUCTURE XLPE C ABLE
1 )
CU / XLPE / PVC 0,6 / 1 kV 1 × 50 mm 2
Construction |
Nominal Thickness(mm) |
Nominal Diameter(mm) |
1-Stranded compacted circular copper conductor |
/ |
8.1 |
2 XLPE insulation |
1.0 |
10.1 |
3-FR-PVC Outer sheath |
1.4 |
12.9 |
2)
CU / XLPE / PVC 0,6 / 1kV 1 × 95 mm 2
Construction |
Nominal Thickness(mm) |
Nominal Diameter(mm) |
1-Stranded compacted circular copper conductor |
/ |
11.5 |
2 XLPE insulation |
1.1 |
13.7 |
3-FR-PVC Outer sheath |
1.5 |
16.7 |
3)
CU / XLPE / PVC 0,6 / 1kV 4 × 16 mm 2
Construction |
Nominal Thickness(mm) |
Nominal Diameter(mm) |
1-Stranded non-compacted circular copper conductor |
/ |
5.0 |
2 XLPE insulation |
0.7 |
6.4 |
3 Filling |
/ |
15.5 |
4 Wrapping tape |
0.2 |
16.1 |
5-FR-PVC Outer sheath |
1.8 |
19.7 |
4)
CU / XLPE / PVC 0,6 / 1kV 4 × 25 mm 2
Construction |
Nominal Thickness(mm) |
Nominal Diameter(mm) |
1-Stranded compacted circular aluminum conductor |
/ |
5.9 |
2 XLPE insulation |
0.9 |
7.7 |
3 Filling |
/ |
18.6 |
4 Wrapping tape |
0.2 |
19.2 |
5-FR-PVC Outer sheath |
1.8 |
22.8 |
3. Caractéristiques techniques garanties
1) CU / XLPE / PVC 0,6 / 1 kV 1 × 50 mm 2
No |
DESCRIPTION |
UNIT |
VALUEREQUIRED |
1 |
Manufacturer |
|
BEIJING HUAYUAN |
2 |
Cable size |
mm2 |
50 |
3 |
Cable type |
|
CU/XLPE/PVC |
4 |
Voltage Grade |
kV |
0.6/1(1.2) |
5 |
Reference Standard |
|
IEC 60228 IEC 60502.1 |
6 |
No. and cross sectional area of conductor |
|
1×50mm2 |
7 |
Conductor material |
|
Copper |
8 |
Shape |
|
stranded compacted circular |
9 |
Nominal diameter of conductor |
mm |
8.1 |
10 |
Insulation material |
|
XLPE |
|
Colour |
|
gray |
11 |
Nominal thickness of insulation |
mm |
1.0 |
12 |
Nominal diameter over insulation |
mm |
10.1 |
13 |
Inner sheath material |
|
NA |
14 |
Nominal thickness of inner sheath |
mm |
NA |
15 |
Outer sheath material |
|
ultraviolet-proof-FR-PVC |
|
Colour |
|
gray |
16 |
Nominal thickness of outer sheath |
mm |
1.4 |
17 |
Nominal overall diameter of cable |
mm |
12.9 |
18 |
Short circuit current rating(t=1.0sec) |
|
|
|
Of conductor |
kA |
7.3(max) |
19 |
Max. conductor temperature in short circuit |
℃ |
250(not exceed 5s) |
20 |
Approx. weight of cable |
kg/km |
458 |
21 |
Minimum bending radius |
mm |
230 |
22 |
Max.D.C. Conductor resistanceat20`C |
Ω/km |
0.387 |
23 |
Max. conductor temperature on continuous |
℃ |
90 |
24 |
Max. current rating in air |
A |
325( temperature 40° C , 1 circuit, flat formation, phase distance 2 diameter of cable) |
25 |
Max. current rating in tunnel |
A |
230(depth of laying 1000 mm ,thermal resistivity of soil 1.2 k.m/W,temperature 25℃, flat formation, phase distance 2 diameter of cable) |
2) CU / XLPE / PVC 0,6 / 1kV 1 × 95 mm 2
No |
DESCRIPTION |
UNIT |
VALUEREQUIRED |
1 |
Manufacturer |
|
BEIJING HUAYUAN |
2 |
Cable size |
mm2 |
95 |
3 |
Cable type |
|
CU/XLPE/PVC |
4 |
Voltage Grade |
kV |
0.6/1(1.2) |
5 |
Reference Standard |
|
IEC 60228 IEC 60502.1 |
6 |
No. and cross sectional area of conductor |
|
1×95mm2 |
7 |
Conductor material |
|
Copper |
8 |
Shape |
|
stranded compacted circular |
9 |
Nominal diameter of conductor |
mm |
11.5 |
10 |
Insulation material |
|
XLPE |
|
Colour |
|
gray |
11 |
Nominal thickness of insulation |
mm |
1.1 |
12 |
Nominal diameter over insulation |
mm |
13.7 |
13 |
Inner sheath material |
|
NA |
14 |
Nominal thickness of inner sheath |
mm |
NA |
15 |
Outer sheath material |
|
ultraviolet-proof-FR-PVC |
|
Colour |
|
gray |
16 |
Nominal thickness of outer sheath |
mm |
1.5 |
17 |
Nominal overall diameter of cable |
mm |
16.7 |
18 |
Short circuit current rating(t=1.0sec) |
|
|
|
Of conductor |
kA |
13.8(max) |
19 |
Max. conductor temperature in short circuit |
℃ |
250(not exceed 5s) |
20 |
Approx. weight of cable |
kg/km |
919 |
21 |
Minimum bending radius |
mm |
300 |
22 |
Max.D.C. Conductor resistanceat20`C |
Ω/km |
0.193 |
23 |
Max. conductor temperature on continuous |
℃ |
90 |
24 |
Max. current rating in air |
A |
370( temperature 40° C , 1 circuit, flat formation, phase distance 2 diameter of cable) |
25 |
Max. current rating in tunnel |
A |
335(depth of laying 1000 mm ,thermal resistivity of soil 1.2 k.m/W,temperature 25℃, flat formation, phase distance 2 diameter of cable) |
3) CU / XLPE / PVC 0,6 / 1kV 4 × 16 mm 2
No |
DESCRIPTION |
UNIT |
VALUEREQUIRED |
1 |
Manufacturer |
|
BEIJING HUAYUAN |
2 |
Cable size |
mm2 |
16 |
3 |
Cable type |
|
CU/XLPE/PVC |
4 |
Voltage Grade |
kV |
0.6/1(1.2) |
5 |
Reference Standard |
|
IEC 60228 IEC 60502.1 |
6 |
No. and cross sectional area of conductor |
|
4×16mm2 |
7 |
Conductor material |
|
Copper |
8 |
Shape |
|
stranded non-compacted circular |
9 |
Nominal diameter of conductor |
mm |
5.1 |
10 |
Insulation material |
|
XLPE |
|
Colour |
|
Black, Blue, Brown, Gray |
11 |
Nominal thickness of insulation |
mm |
0.7 |
12 |
Nominal diameter over insulation |
mm |
6.4 |
13 |
Inner sheath material |
|
NA |
14 |
Nominal thickness of inner sheath |
mm |
NA |
15 |
Outer sheath material |
|
ultraviolet-proof-FR-PVC |
|
Colour |
|
gray |
16 |
Nominal thickness of outer sheath |
mm |
1.8 |
17 |
Nominal overall diameter of cable |
mm |
19.7 |
18 |
Short circuit current rating(t=1.0sec) |
|
|
|
Of conductor |
kA |
2.4(max) |
19 |
Max. conductor temperature in short circuit |
℃ |
250(not exceed 5s) |
20 |
Approx. weight of cable |
kg/km |
721 |
21 |
Minimum bending radius |
mm |
300 |
22 |
Max.D.C. Conductor resistanceat20`C |
Ω/km |
1.15 |
23 |
Max. conductor temperature on continuous |
℃ |
90 |
24 |
Max. current rating in air |
A |
75( temperature 40° C , 1 circuit, flat formation, phase distance 2 diameter of cable) |
25 |
Max. current rating in tunnel |
A |
92(depth of laying 1000 mm ,thermal resistivity of soil 1.2 k.m/W,temperature 25℃, flat formation, phase distance 2 diameter of cable) |
4) CU / XLPE / PVC 0,6 / 1kV 4 × 25 mm 2
No |
DESCRIPTION |
UNIT |
VALUEREQUIRED |
1 |
Manufacturer |
|
BEIJING HUAYUAN |
2 |
Cable size |
mm2 |
25 |
3 |
Cable type |
|
CU/XLPE/PVC |
4 |
Voltage Grade |
kV |
0.6/1(1.2) |
5 |
Reference Standard |
|
IEC 60228 IEC 60502.1 |
6 |
No. and cross sectional area of conductor |
|
4×25mm2 |
7 |
Conductor material |
|
Copper |
8 |
Shape |
|
stranded compacted circular |
9 |
Nominal diameter of conductor |
mm |
5.9 |
10 |
Insulation material |
|
XLPE |
|
Colour |
|
Black, Blue, Brown, Gray |
11 |
Nominal thickness of insulation |
mm |
0.9 |
12 |
Nominal diameter over insulation |
mm |
7.7 |
13 |
Inner sheath material |
|
NA |
14 |
Nominal thickness of inner sheath |
mm |
NA |
15 |
Outer sheath material |
|
ultraviolet-proof-FR-PVC |
|
Colour |
|
gray |
16 |
Nominal thickness of outer sheath |
mm |
1.8 |
17 |
Nominal overall diameter of cable |
mm |
22.8 |
18 |
Short circuit current rating(t=1.0sec) |
|
|
|
Of conductor |
kA |
3.7(max) |
19 |
Max. conductor temperature in short circuit |
℃ |
250(not exceed 5s) |
20 |
Approx. weight of cable |
kg/km |
1063 |
21 |
Minimum bending radius |
mm |
340 |
22 |
Max.D.C. Conductor resistanceat20`C |
Ω/km |
0.727 |
23 |
Max. conductor temperature on continuous |
℃ |
90 |
24 |
Max. current rating in air |
A |
92( temperature 40° C , 1 circuit, flat formation, phase distance 2 diameter of cable) |
25 |
Max. current rating in tunnel |
A |
126(depth of laying 1000 mm ,thermal resistivity of soil 1.2 k.m/W,temperature 25℃, flat formation, phase distance 2 diameter of cable) |
4 . EXIGENCES D'ESSAI POUR LES CÂBLES D'ALIMENTATION BT
L'essai du câble doit être effectué conformément à la norme applicable des câbles d'alimentation de 0,6 / 1 kV. Les éléments d'essai suivants doivent être réalisés conformément aux normes CEI pertinentes.
No. |
Test item |
Routine tests |
|
1 |
measurement of the electrical resistance of conductors |
2 |
Voltage test |
Sample tests |
|
1 |
conductor examination |
2 |
check of dimensions |
3 |
Hot set test for XLPE insulation |
5. PARTICULARITÉS D' EMBALLAGE POUR CÂBLE DE PRODUCTION 0 .6 / 1 kV
Les câbles doivent être enroulés sur des tambours en acier. Le marquage indélébile doit être imprimé sur la surface de la bride du tambour conformément aux exigences du client.
Cable Type |
Drum length(m) |
Drum Dimensions (mm) |
|||
D |
d |
L2 |
L1 |
||
CU/XLPE/PVC 0.6/1kV-1C*50mm2 |
1000 |
1000 |
450 |
450 |
550 |
CU/XLPE/PVC 0.6/1kV-1C*95mm2 |
1000 |
1250 |
690 |
580 |
700 |
CU/XLPE/PVC 0.6/1kV-4C*16mm2 |
500 |
1250 |
690 |
580 |
700 |
CU/XLPE/PVC 0.6/1kV-4C*25mm2 |
500 |
1250 |
690 |
580 |
700 |
Note: La valeur [D "ne doit pas contenir la dimension des plaques d'étanchéité.
Notre Fantory
Paquet
Livraison
Honneur
La tension du câble d'alarme d'incendie, du câble d'alarme d'incendie de sécurité, du câble ignifuge, du câble de résistance au feu tout pourrait être le câble 0.6 / 1kv ou le câble 1kv ou le câble 0.6kv.
Beijing, Beijing, China
Envoyez votre demande à ce fournisseur